Sign In | Join Free | My webtextiles.com
China Advanced Instruments Co.,Limited logo
Advanced Instruments Co.,Limited
Advanced Instruments Co.,Limited To Be Advanced in Quality and Service!
Verified Supplier

6 Years

Home > Oil Test Equipment >

4530F PC Controlled Atomic Absorption Spectrophotometer with 8 Turrets

Advanced Instruments Co.,Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

4530F PC Controlled Atomic Absorption Spectrophotometer with 8 Turrets

Brand Name : AI

Model Number : 4530F

Certification : ISO

Place of Origin : China

MOQ : 1 set 4530F Atomic Absorption Spectrophotometer

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 200 sets per month

Delivery Time : 20 days

Packaging Details : 4530F Atomic Absorption Spectrophotometer packed in Plywood case

Test method : Atomic Absorption Spectrometry AAS

Wavelength Range : 190 ~ 900nm

Wavelength Accuracy : ±0.15nm

Lamp Turrets : 8 PCS

Spectrum Bandwidth : 0.1nm, 0.2nm, 0.4nm, 1.0nm And 2.0nm

Operation : PC controlled

Power supply : AC220V±10%/50HZ

Warranty : 1 Year

Contact Now

4530F PC Controlled Flame Graphite Furnace Atomic Absorption Spectrophotometer

Features:
This AAS machine is complete automatic controlling system;
The AA spectrophotometer can be worked with advanced graphite furnace temperature controlling technology;
Safe, reliable and convenient flame system;
Multi-functional software workstation;
This flame system atomic absorption spectrophotometer is ompletely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional);
Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term;
Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp;
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions;
Fully automated wavelength scanning and peak searching;
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout;
Deuterium lamp and self-absorption background regulation;
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called;
Measuring method of AAS machine: flame absorption method and emission method;
Result printing: parameter printing, data result printing and diagram printing;

Instrument Configuration:

Atomic Absorption Spectrophotometer 1pc
Air compressor without noise 1pc
PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)

Specifications:

Wavelength range 190 ~ 900nm
Spectral bandwidth Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Accuracy of the wavelength ±0.15nm
Receptivity of the wavelength ≤0.04nm
Base line stability ≤0.002A/30min (Cu)
Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
Preciseness 0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand Eight lamps
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight 700mm×550mm×450mm 75Kg
Power source 220V±22V AC


Flame System:

Acetylene air burner 100mm
Nitrous oxide acetylene flame head 50mm
Ignition dynamic baseline drift ≤0.006A/30min
(Cu) Characteristic viscosity ≤0.025μg/ml/1%
Related standard deviation of the accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety system Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner


Graphite Furnace:

The highest temperature 3000℃
The largest temperature rising speed ≥2000℃/S
Characteristic quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size and weight 550mm×450mm×300mm 65Kg
Safety system Over current protection
Protection Low air pressure alarm, low cooling water flow alarm
Power source and power 220V±22V AC 7000W


Product Tags:

Atomic Absorption Spectrophotometer

      

AA Spectrophotometer

      

4530F Atomic Absorption Spectrophotometer

      
Quality 4530F PC Controlled Atomic Absorption Spectrophotometer with 8 Turrets for sale

4530F PC Controlled Atomic Absorption Spectrophotometer with 8 Turrets Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Advanced Instruments Co.,Limited
*Subject:
*Message:
Characters Remaining: (0/3000)